1.OUT LINE
HANDY-700 ,a compact type printer with various functions which may be used
as a hand-held/belt-hung, Battery-operated unit, Infrared interface or as desk-
top/wall-hung unit to meet a today printing needs.
1-1.FEATURES
*. Ultra small-sized portable and desk-top configuration.
*. Quiet and fast printing(50mm/sec) using the direct line thermal printing
method.
* One(1) hour continuous printing with fully charged Lit-ion battery
*. Extremely easy to load a paper by CLAMSHELL unit.
*. Easy maintenance and head cleaning.
*. Setting the baud rate, handshaking, International Characters, density ETC.
by external button.
*. Support for many bar code types(JAN/EAN-8,JAN/EAN-13,
CODE39,CODE128,CODE93).
*. Command selection of font sizes(12x24,8x16).
*. Current printer status.
*. Auto online mode
*. Self-test facility
*. Dump mode function.
Page view 0
1 2 3 4 5 6 ... 28 29

Summary of Contents

Page 1 - 1.OUT LINE

1.OUT LINE HANDY-700 ,a compact type printer with various functions which may be used as a hand-held/belt-hung, Battery-operated unit, Infrare

Page 2 - Handy700 – R S B

 Cleaning the print-head Depending of the environment in which the printer is used, The print-head may The print-head may accumulate dust. Therefore

Page 3 - 2.General Guide

IrDA Protocol 1. Transmission control character SYMBOL VALUE SYMBOL VALUE SOH STX ETX PR_RES(ACK) PR_RES(NAK) 01h 02h 03h 06h 15

Page 4 - 2-3.Power supply

3.2 Data format  <Start Response> <Start Command>

Page 5

Data2 Command   Data2 Response(Ack) End Command   End Response(Ack) 4.3 Normal phase 3 Host Direction Printer Start Command   Start

Page 6

Data1 Command (Wait 0.5sec )   (No action due to receipt of no command) Data1 Command   Data1 Response(Ack) Data2 Command   Data2 Response(N

Page 7 - 3.Operation

 Data Response(Ack) End Command  End Command  End Command (Because there was nornal printing action,This case does not involve in error)  (N

Page 8

Command Summary Command Name Page HT Horizontal tab LF Print and line feed FF (1)Print and return (2)Print and feed label to print starting pos

Page 9 - 3-7.Maintenance

HT(Horizontal tab) [Format] ASCII : HT Hex : 09 Decimal : 9 [Descripti

Page 10 - 3-8.Connectors & Cables

[EX] Data : “12345”,18h,”ABCDE”,0Ah Print : ESC FF(Print data in label mode) [Format]

Page 11 - IrDA Protocol

ESC * m nL nH[d1…dk](Select bit-image mode) [Format] ASCII : ESC * m nL nH [d1…dk] Hex : 1B 2A m nL nH

Page 12

1-2. Printer Parts & Accessories. 1-2-1 Printer parts : 1) Printer cover 2) Operation panel 3) Power connector 4) Interface

Page 13 - 5. Abnormal transmission

ESC 2(Set default line spacing) [Format] ASCII : ESC 2 Hex : 1B 32 Decimal :

Page 14 - (Due to no response,Waiting

ESC R n(Select international character set) [Format] ASCII : ESC R n Hex : 1B 52 n Deci

Page 15

ESC { n(Set/cancel upside-down character printing) [Format] ASCII : ESC { n Hex : 1B 7B n

Page 16 - Command Summary

GS H n(Select printing position of HRI characters) [Format] ASCII : GS H n Hex : 1D 48 n De

Page 17 - (Cancel print data)

32,36,37,43,45,46,47 5 ITF 1 ≤k 48 ≤d ≤57 6 CODABAR(NW-7) 1 ≤k 48 ≤d ≤57, 65 ≤d ≤68 36,43,45,46,47,58 7 CODE128A 2 ≤k 0 ≤d ≤127 8 CODE128B 2 ≤k 0

Page 18 - (Set absolute print position)

GS x n(Set bar code print starting position) [Format] ASCII : GS x n Hex : 1D 78 n

Page 19 -

Hex : 12 6d s nL nH Decimal : 18 109 s nL nH [Description] Sets the length of mark potion in label mode.

Page 20 - (Print and feed paper)

DC2 v nL nH(Set LSB bit image) [Format] ASCII : DC2 v nL nH Hex : 12 76 nL nH

Page 21 - (Transmit printer status)

n Cuntry n Cuntry 0 Korea 3 Japan 1 U.S.A 4 Euro 2 England 5

Page 23 - (Print bar code)

B(Battery with external charging) C(Battery with internal charging) 2.General Guide. 2-1.Description of printer

Page 24 - (Select bar code width)

The Interface connector is fitted at right side of printer. This is 6pins RJ connector for RS-232C Communication. 2-1-4.Belt rack holes There

Page 25

2-3-2 Battery 1) Kind of Specified Products Name : Camcorder battery pack Pack type : IN-5XL Cell type : LITHIUM-ION 2) Basic

Page 26 - DC2 V nL nH

2-4.Specifications. Printing method Direct thermal No. of columns 32 columns : 384 dots/lines Character size 1.5mm x 3.0mm (12x 24) Line

Page 27 - (Select code system)

3.Operation. 3-1.Precautions for installation. HANDY-700 Printer may be installed in a variety of applications but, to Maintain your unit in optim

Page 28

NOTE : If there are unprinted data in the memory after changing paper, The printer Go into online mode automatically and print the rema

Page 29

3-5.Set-up mode. Following thease step when setting the program. Turn ON the power while pressing SEL button then printer will go into set-up Mode